Product Details:
|
|
| Place of Origin: | Suzhou, China |
|---|---|
| Brand Name: | GoGo |
| Certification: | ISO 9001:2015 / ISO 14001:2015 / ISO 45001:2018 |
| Model Number: | H600S |
|
Payment & Shipping Terms:
|
|
| Minimum Order Quantity: | 1 |
| Price: | CNY 30000~600000/set |
| Packaging Details: | Cardboard box + wooden box |
| Delivery Time: | 30~60 work days |
| Payment Terms: | ,T/T |
| Supply Ability: | 1set/day |
|
Detail Information |
|||
| Name: | Temperature Controlled Microscope Stage | Cooling/Heating Method: | Resistance Heating |
|---|---|---|---|
| Temperature Range: | RT~600℃ | Temperature Stability: | ±0.1℃ |
| Heating/Cooling Rate: | Maximum Heating Rate:50℃/min,Controllable Cooling Rate | Sample Holde: | Silver ;23mm*23mm |
| Optical Path: | Reflection / Transmission(φ2mm Optical Access Hole) | Top Window Size: | φ25mm*1mm |
| Window Material: | JGS2 Fused Silica Glass (Transmission Range: 220 Nm - 2500 Nm), Manually Removable And Replaceable. | Distance From Window Upper Surface To Sample Holder Upper Surface: | 4.5mm |
| Chamber Height: | 3.5mm | Chamber: | Atmosphere |
| Dimensions: | 91mm*97mm*24mm | Net Weight: | 0.4kg |
| Basic Configuration: | TNEX*1、Optical Heating Stage*1、 Temperature Controller*1、Recirculating Chiller*1、Cables、Tubing、and Accessories | Optional: | Adapter Plate/Customized Recirculating Chiller/Computer Host/ Customed Temperature Control Software |
| Highlight: | Versatile Temperature Controlled Microscope Stage,Compact Microscope Heated Stage,Microscope Heated Stage Precision |
||
Product Description
Microscope Heating Stage with Precise Control up to 600°C, ±0.1°C Temperature Stability, and 50°C/min Heating Rate for Raman and Optical Analysis
The GoGo H600S is a versatile and compact Microscope Heating Stage engineered for precise thermal analysis in materials science and life sciences. Offering a temperature range from ambient to 600°C with exceptional stability of ±0.1°C, this stage enables high-quality in-situ microscope observation and Raman spectroscopy. Its innovative silver sample holder ensures excellent thermal conductivity and uniformity. Designed for both reflection and transmission optical paths—the latter via a dedicated φ2mm access hole—the H600S provides researchers with flexible imaging modalities for studying thin films, polymers, biological samples, and nanomaterials under controlled thermal conditions.
Superior Thermal Precision: Experience highly accurate and stable temperature control with ±0.1°C stability, essential for sensitive experiments and reproducible results in quantitative analysis.
Optimized for Raman & Optical Clarity: The combination of a high-transmission JGS2 silica window and a dual optical path design makes this Microscope Heating Stage particularly effective for Raman spectroscopy and high-resolution optical imaging, minimizing background interference.
Efficient Thermal Performance: Features a rapid heating rate of 50°C/min and integrated active cooling via a recirculating chiller, enabling efficient thermal cycling and protecting sample integrity.
Compact & User-Friendly Design: With a lightweight (0.4kg) and low-profile build (chamber height: 3.5mm), this stage is easily integrated onto most microscope platforms without compromising stage travel or optical working distance.
Intelligent Software Integration: The included TNEX software platform provides seamless computer control for programming complex temperature profiles, automating experiments, and synchronizing data acquisition from multiple instruments.
| Feature | Specification |
|---|---|
| Model / Brand | H600S / GoGo |
| Certifications | ISO 9001:2015, 14001:2015, 45001:2018 |
| Temperature Range | RT to 600°C |
| Temperature Stability | ±0.1°C |
| Max Heating Rate | 50°C/min |
| Sample Holder | Silver, 23mm x 23mm |
| Optical Path | Reflection / Transmission (φ2mm hole) |
| Top Window | φ25mm x 1mm, JGS2 Fused Silica |
| Working Distance | 4.5mm |
| Dimensions & Weight | 91mm x 97mm x 24mm / 0.4kg |
| Core Control Software | TNEX Platform |
This precision Microscope Heating Stage is successfully implemented across diverse international markets, including Southeast Asia, the Middle East, Russia, and Africa. It is an invaluable tool for university laboratories, governmental research institutes, and innovative companies in sectors such as nanotechnology, pharmaceuticals, and advanced materials development.
What are the primary applications for the H600S Microscope Heating Stage?
It is ideal for in-situ studies requiring precise heating, such as polymer phase transitions, chemical reaction monitoring, crystal growth observation, and temperature-dependent Raman spectral analysis.
How does the silver sample holder benefit my experiment?
The silver holder provides faster thermal response and superior temperature uniformity across the sample compared to ceramic alternatives, leading to more consistent and reliable data.
Can I use this stage for transmission-mode microscopy?
Yes. This Microscope Heating Stage features a unique transmission optical path with a φ2mm access hole, allowing for trans-illumination experiments on thin samples.
Is the system ready to use upon delivery?
Absolutely. The basic configuration includes the heating stage, a programmable temperature controller, TNEX software, a recirculating chiller, and all necessary cables—forming a complete, plug-and-play system.
What support is available for software and operation?
Comprehensive support for the TNEX software is provided, including detailed manuals, instructional videos, and direct technical assistance to ensure smooth integration into your workflow.