Precise Temperature Control Thermal Stage XY Manipulation Microscope Cooling Stage Versatile

Product Details:
Place of Origin: Suzhou, China
Brand Name: GoGo
Certification: ISO 9001:2015 / ISO 14001:2015 / ISO 45001:2018
Model Number: CH600S-XY/CH400SV-XY
Payment & Shipping Terms:
Minimum Order Quantity: 1
Price: CNY 30000~600000/set
Packaging Details: Cardboard box + wooden box
Delivery Time: 30~60 work days
Payment Terms: T/T
Supply Ability: 1set/day
Contact Now Chat Now

Detail Information

Name: Thermal Stage Cooling/Heating Method: Liquid Nitrogen Cooling,Resistance Heating
Temperature Range: -190℃~600℃/-190℃~400℃ Temperature Stability: ±0.1℃
Heating/Cooling Rate: Maximum Heating Rate:150℃/min,Maximum Cooling Rate:40℃/min Sample Holder: Silver ;23mm*23mm
Optical Path: Reflection / Transmission(φ2mm Optical Access Hole) Top Window Size: φ20mm*0.3mm/φ25mm*1mm
Bottom Window Size: φ10mm*1mm(Transmitted Light Option) Window Material: JGS2 Fused Silica Glass (Transmission Range: 220 Nm - 2500 Nm), Manually Removable And Replaceable.
Window Defrosting: Gas Purge Attachment,Air Blowing Defrosting At Low Temperatures Distance From Window Upper Surface To Sample Holder Upper Surface: 5.1mm
Chamber Height: 4.8mm Chamber: Atmosphere/Vacuum
Sample Displacement: X/Y-axis Travel Range: ±6mm, Positioning Accuracy: 0.01mm Microscope Slide: φ16mm*0.15mm
Dimensions: 86mm*100mm*21.5mm Net Weight: 0.7kg/0.8kg
Basic Configuration: TNEX*1、Optical Heating And Cooling Stage*1、 Temperature Controller*1、Cooling Controller*1、Liquid Nitrogen Tank*1、Recirculating Chiller*1、Cables、Tubing、and Accessories Optional: Adapter Plate/Customized Liquid Nitrogen Tank/Customized Recirculating Chiller/Vacuum System/Computer Host/ Customed Temperature Control Software
Highlight:

Precise Temperature Control Thermal Stage

,

XY Manipulation Microscope Cooling Stage

,

Microscope Cooling Stage Versatile

Product Description

 
Precise Temperature Control Heating Cooling Stage with XY Sample Manipulation ±6mm and Liquid Nitrogen Cooling for Microscope Observation

Product Title: GoGo CH600S-XY/CH400SV-XY Heating Cooling Microscope Stage with XY Sample Manipulation (-190°C to 600°C)

Product Introduction
The GoGo CH600S-XY/CH400SV-XY is a versatile, high-precision Heating Cooling Stage engineered for demanding in-situ analysis across an extreme temperature spectrum from -190°C to 600°C. Designed for applications requiring both rapid thermal cycling and precise spatial control, this stage integrates a motorized XY sample manipulator, allowing for ±6mm of travel with 0.01mm accuracy. This enables researchers to reposition specific sample regions under the objective without interrupting the thermal environment. As a comprehensive Heating Cooling Microscope Stage, it supports a wide array of applications, from phase transition studies and material characterization under vacuum to vertical integration in FTIR spectrometers, all controlled seamlessly by the TNEX software platform.

Key Advantages & Why Choose Our System

  • Unmatched Thermal Range & Control: Perform experiments spanning nearly 800°C in one integrated system. Achieve rapid heating up to 150°C/min and controlled cooling via liquid nitrogen, all with exceptional ±0.1°C stability, making this a uniquely capable Heating Cooling Stage.
  • Precision XY Sample Manipulation: The integrated XY translation stage allows detailed mapping and multi-point analysis on a single sample at any temperature, significantly enhancing experimental efficiency and data richness.
  • Advanced Optical & Environmental Flexibility: Equipped with high-transmission JGS2 windows for Raman, UV-VIS, and IR studies. The system supports vacuum/gas environments and includes a gas purge accessory to prevent window frosting during cryogenic operation, ensuring clear observation.
  • Complete Digital Integration with TNEX: The TNEX software provides full computer control for programming complex temperature profiles, automating the XY movement, recording the entire experiment with synchronized video, and exporting all data for in-depth analysis.
  • Proven Platform with Certified Quality: As one of the most widely used stages in its class, it is manufactured under ISO 9001, 14001, and 45001 certified processes and comes as a complete turnkey solution ready for immediate deployment.

Technical Specifications

Parameter Specification
Model CH600S-XY (600°C) / CH400SV-XY (400°C)
Temperature Range -190°C to 600°C / -190°C to 400°C
Temperature Stability ±0.1°C
Max Heating/Cooling Rate Heat: 150°C/min; Cool: 40°C/min
Sample Holder Silver, 23mm x 23mm
Sample Manipulation XY Travel: ±6mm; Accuracy: 0.01mm
Optical Path Reflection & Transmission (φ2mm hole)
Defrosting System Gas Purge Attachment
Core Control Software TNEX Platform

Target Markets & Clients
This advanced Heating Cooling Microscope Stage is instrumental for researchers in growth markets including Southeast Asia, the Middle East, Russia, and Africa. It is the preferred choice for university laboratories, government research institutes, and industrial R&D centers specializing in materials science, semiconductors, pharmaceuticals, and geology.

Frequently Asked Questions (FAQ)

  1. What is the primary benefit of the XY movement in this Heating Cooling Stage?
    The XY translation allows you to precisely scan different areas of a sample while maintaining stable temperature conditions, which is crucial for studying heterogeneous materials, mapping properties, or observing multiple cells or inclusions in a single experimental run.
  2. How is window frosting managed at very low temperatures?
    The stage includes a dedicated gas purge (air or dry nitrogen) attachment. This airflow keeps the observation window clear of frost and condensation, ensuring uninterrupted optical access during sub-zero experiments.
  3. Can this stage be used for spectroscopic applications beyond microscopy?
    Yes. With optional holders, this versatile Heating Cooling Stage can be mounted vertically in FTIR spectrometers. Its transmission optical path and wide spectral window materials also make it suitable for various optical spectroscopy techniques.
  4. What is included in the basic system package?
    The package is comprehensive, including the main stage with XY control, temperature and refrigeration controllers, a liquid nitrogen tank, a recirculating chiller, TNEX software, and all essential cables and tubing.
  5. Is the TNEX software capable of controlling the XY movement?
    Yes, the TNEX software fully integrates control of both the temperature profiles and the XY sample positioning, enabling automated, coordinated workflows for complex experimental sequences.

Get in touch with us

Enter Your Message

You Might Be Into These